Symmetricom 5401 User Manual

Page of 40
PN 8500-0150, Rev. A, May 2005
19
Operating Manual
Operation
Set Defaults 
Command Format: 
Description:
Returns the unit to a default state.
Table 2  Default Values
Parameter
Default Value
Discipline
On
Dynamic Gain Floor
4
Dynamic Gain Ceiling
30
Dynamic Gain Rate Factor
0.0005 ns
Dynamic Gain Offset Factor
5.0 ns
Km
0.99997
Ko1
0.99984
Ko2
0.99984
Disgain
1280
Resync Threshold
µs
Resync Delay
60 seconds
Rate Threshold
0.04 
µs
Burst
On
DAC
32767
Start-up Parameters
See 
Default Calibrate Unit (Cable Delay)
0
1PPS Offset
0
Input Threshold
High
Programmable Delay Value
036
Oscillator Control Range
5e-9
Design Verification
Off
Rate Error TC
0.9995
Offset Error TC
0.9995