Symmetricom 5401 User Manual

Page of 40
PN 8500-0150, Rev. A, May 2005
21
Operating Manual
Operation
Description: 
 is a list of the data found in the response. The data is in the same format as the 
associated "Enter" command. A space exists between each of the parameters, except where 
noted. The total count is 176 characters.
Input Threshold High/Low 
Command Format: 
Table 3  Response Format
Variable
Return String
Count
First
Dynamic Gain Floor
DFgg.g
6
1
Dynamic Gain Ceiling
DCgg.g
6
8
Dynamic Gain Rate Factor
DRrr.rrrr (in nanoseconds)
9
15
Dynamic Gain Offset Factor
DOoooo (in nanoseconds)
5
25
Km
KM.kkkkkk
9
31
Ko1
KO1.nnnnnn
10
41
Ko2
KO2.oooooo
10
52
Disgain
DGddddd
7
63
Resync Threshold
RTrrrrrr.rrr (in microseconds)
12
71
Resync Delay
RDdddd (in microseconds)
6
84
Rate Threshold
RArrrrrr.rrr (in microseconds)
12
91
Burst
BUx (x = 0 = Off, x =1 = On)
3
104
Default Calibrate Unit
CZrr.rrrr (in microseconds)
9
108
1PPS Offset
POyyyyyy.yyy (in microseconds)
12
118
Input Threshold
ITx (x = 0 = High, x = 1 = Low)
3
131
Programmable Delay Value
PDddd
5
135
Oscillator Control Range
ORsrr.rrrr (in microseconds)
10
141
Design Verification
DVx (x = 0 = Off, x = 1 = On)
3
152
Rate Error TC
RCnnnnnn
8
156
Offset Error TC
Ocoooooo (no space here)
165
CR LF
2
174