Symmetricom 5401 User Manual

Page of 40
Operating Manual
Operation
PN 8500-0150, Rev. A, May 2005
20
Response Format:
Enter 1 PPS Offset (not implemented) 
Command Format: 
Description: 
yyyyyy.yyy - 1 PPS Offset; yyyyyy.yyy (0 to 999999.999 microseconds) is amount of extra 
delay applied to the 1 PPS output. It is added to the unit zero point and the resync side load 
value. 
Response Format:
Request Setup Parameters 
Command Format: 
 Note 1: Start-up Parameters
N
Dynamic Gain
Time
1
.1
360
2
99
1140
3
60
1740
4
30
2760
5
20
0
6
11
0
Note: There is a hardware limitation on the resync control of approximately 
±12 microseconds. Any 1 PPS offset values outside of this range will change the zero 