Xantrex Technology 10 User Manual

Page of 68
Installation Precautions
975-0251-01-01
2–3
Key Installation Points
Observe proper polarity when connecting batteries. Reverse DC polarity 
will result in damage to the Freedom 10.
Do not backfeed the AC output of the inverter with incoming AC power. 
Double check all aspects of your AC wiring for the possibility of backfeeding. 
A backfeed will cause significant damage to your unit.
Do not connect the AC input to the AC output. In effect, this would be 
plugging the battery charger into the inverter. This could occur if the Freedom 
10 is connected to the entire leg of a circuit breaker panel, then a circuit 
breaker on that leg is used to feed the battery charger. This will cause the unit 
to oscillate on and off when the unit is in inverter mode.
Always use properly sized wire and connectors, keeping in mind that 
considerable amperage flows in the DC circuit. Fusing the positive DC cable 
is required.
Keep the Freedom 10 out of the elements and out of direct contact with 
water.
 Remember that the unit is a piece of electronic equipment and treat it 
accordingly.
Mount the unit as close to the batteries as possible but not in the presence 
of flammable fumes or in an enclosed battery compartment.
Do not bolt the unit down until the AC, remote, and ground wiring is 
completed.