Toshiba e-STUDIO4500c/5500c User Manual

Page of 1120
ADDITIONAL INFORMATIONS 
April 2007 
4-92 
4.4.8  LOW POWER MODE TEMPERATURE 
SYMPTOM: 
Fusing hot roller yield may decrease, or, the fusing hot roller could get damaged in 
the worst case. 
 
CAUSE: 
Hot roller has been exposed to excessive heat by the fusing lamp inside the Hot 
Roller. 
 
ACTION: 
  Never increase the Low Power Mode temperature setting (SP 1202 11) for the 
fusing lamp inside the Hot Roller higher than default setting. 
 
SP number 
Description 
Value 
Function 
SP 1202 11 
Hot Roller 
Energy Saver2 
(Hot roller temperature 
in Low Power Mode) 
Default: -50 
Adjustable range: 0 to 
-200 
The value set by this SP 
determines the additional 
value applied to the Hot 
roller temperature in 
Stand-by mode.  
 
Default value (-50) means that the hot roller temperature in Low Power Mode is 
"Hot Roller temperature in Stand-by mode minus 50 degrees". This setting is 
correct. 
 
Example: If you set -30, the hot roller temperature in Low Power Mode will be 
"Hot Roller temperature in Stand-by mode minus 30 degrees". This setting is 
not good for Hot Roller yield. 
 
Example: If you set -80, the hot roller temperature in Low Power Mode will be 
"Hot Roller temperature in Stand-by mode minus 80 degrees". This setting is 
correct. 
 
   Please instruct the end user that if the "Energy Saver Timer" is set longer than 
its default (15minutes by User Tool) the fusing hot roller yield may decrease 
according to the machine condition.  
 
NOTE:  End user can change the "Energy Saver Timer" with the following 
procedure. 
   User 
Tools 
 System Settings 
 Timer Settings 
 Energy Saver Timer