Motorola TMS320C6711D User Manual

Page of 107
        
SPRS292A − OCTOBER 2005 − REVISED NOVEMBER 2005
62
POST OFFICE BOX 1443 
 HOUSTON, TEXAS 77251−1443
absolute maximum ratings over operating case temperature range (unless otherwise noted)
† 
Supply voltage range, CV
DD
 (see Note 2)
− 0.3 V to 1.8 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Supply voltage range, DV
DD
 (see Note 2)
−0.3 V to 4 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Input voltage range
−0.3 V to DV
DD
 + 0.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Output voltage range
−0.3 V to DV
DD
 + 0.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Operating case temperature ranges, T
C
(default)
0
_
C to 90
_
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
(A version) [
C6711DGDPA and C6711DZDPA
]
−40
_
C to105
_
C
. . . 
Storage temperature range, T
stg
−65
_
C to 150
_
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 2: All voltage values are with respect to VSS
.
recommended operating conditions
 
MIN
NOM
MAX
UNIT
CVDD
Supply voltage, Core
−250 only
1.33
1.4
1.47
V
CVDD
Supply voltage, Core
1.14§
1.20§
1.32
V
DVDD
Supply voltage, I/O
3.13
3.3
3.47
V
VSS
Supply ground
0
0
0
V
VIH
High-level input voltage
All signals except CLKS1, DR1, and RESET
2
V
VIH
High-level input voltage
CLKS1, DR1, and RESET
2
V
VIL
Low-level input voltage
All signals except CLKS1, DR1, and RESET
0.8
V
VIL
Low-level input voltage
CLKS1, DR1, and RESET
0.3*DVDD
V
IOH
High-level output current¶
All signals except ECLKOUT, CLKOUT2, CLKS1, and 
DR1
–8
mA
IOH
High-level output current¶
ECLKOUT and CLKOUT2
–16
mA
IOL
Low-level output current¶
All signals except ECLKOUT, CLKOUT2, CLKS1, and 
DR1
8
mA
IOL
Low-level output current¶
ECLKOUT and CLKOUT2
16
mA
CLKS1 and DR1
3
mA
TC
Operating case 
temperature
Default
0
90
_
C
VOS
Maximum voltage during overshoot (See Figure 19)
4#
V
VUS
Maximum voltage during undershoot (See Figure 20)
−0.7#
V
TC
Operating case 
temperature
A version (C6711DGDPA and C6711DZDPA)
–40
105
_
C
‡ The core supply should be powered up prior to (and powered down after), the I/O supply. Systems should be designed to ensure that neither
supply is powered up for an extended period of time if the other supply is below the proper operating voltage.
§ These values are compatible with existing 1.26−V designs.
¶ Refers to DC (or steady state) currents only, actual switching currents are higher. For more details, see the device-specific IBIS models.
# The absolute maximum ratings should not be exceeded for more than 30% of the cycle period.