Fujitsu FR81S User Manual

Page of 2342
CHAPTER 31: LOW-VOLTAGE DETECTION (INTERNAL 
LOW-VOLTAGE DETECTION) 
 
 
4. Registers 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : 
INTERNAL LOW-VOLTAGE DETECTION (INTERNAL POWER SUPPLY 
LOW-VOLTAGE 
DETECTION) 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
[bit3] LVD_OE (Low Voltage Detect power fall Output Enable) 
This bit enables the output of the signal when a fall of the internal power supply voltage is detected. 
 
LVD_OE 
Internal voltage fall detection output 
enable setting 
Enable 
Disable 
*This bit is initialized by only power-on reset. 
[bit2, bit1] Reserved 
 
[bit0] LVD_F (Low Voltage Detect power fall Flag) : Internal low-voltage detection flag 
This bit indicates an internal power supply voltage fall detection flag. 
LVD_F 
Internal power supply fall detection flag 
Read 
Write 
Not detected 
Clear the flag 
Detected 
No effect on operation 
If a power-on reset or a drop in the internal power supply voltage is detected, the LVD_F bit is set to "1". 
It will be initialized only when the external reset is input. 
 
 
MB91520 Series
MN705-00010-1v0-E
1149