5.4.1.   Main Clock Oscillation Stabilization Wait Timer (Main 
Timer) 
The main clock oscillation stabilization wait timer (Main Timer) is explained. 
The main timer is operated by the main clock (MCLK). It is used for the main clock stabilization time counter. 
When main clock is stabilized, the timer can be used as the timer which generates interrupt after the specified 
period.   