CHAPTER 19: BASE TIMER 
 
 
5. Operation 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER
 : BASE TIMER 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
52 
   Output Waveform 
The waveform (TOUT signal) of the 16/32-bit reload timer can be output. The waveform (TOUT signal) to be 
output varies according to the setting of the OSEL bit of the base timer x timer control register (BTxTMCR). 
Table 5-1 Correspondence between Output Polarities and Output Waveforms 
Output polarity 
Output waveform 
Normal polarity   
(OSEL = 0) 
"L" level pulse is output when counting starts. 
Thereafter, the output level is inverted every time an underflow occurs. 
Inverted polarity   
(OSEL = 1) 
"H" level pulse is output when counting starts. 
Thereafter, the output level is inverted every time an underflow occurs. 
 
Figure 5-8 shows the output waveform in reload mode. 
Figure 5-8 Output Waveform in Reload Mode (Normal Polarity) 
 
TI O A0, TIOA1 pins 
CTEN bit 
Opposite (Inversion) level when OSEL=1 
Activation trigger 
Underflow 
MB91520 Series
MN705-00010-1v0-E
685