Fujitsu FR81S User Manual

Page of 2342
CHAPTER 24: 16-BIT FREE-RUN TIMER 
 
 
4. Registers 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER : 16-BIT FREE-RUN TIMER 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
4.1.  Registers for the Free-run Timer Simultaneous 
Activation 
Registers for the free-run timer simultaneous activation are explained. 
The free-run simultaneous activation consists of the timer synchronous activation register and the timer 
synchronous enable register. 
4.1.1. 
Timer Synchronous Activation Register : (TCGS) 
The timer synchronous activation register (TCGS) is used for enabling simultaneous timer and controlling 
simultaneous timer clear of the free-run timer. The free-run timer for enabling and clearing the simultaneous 
timer can be set by the timer synchronous activation enable register (TCGSE). 
  TCGS: Address 1200
H
 (Access: Byte, Half-word, Word) 
 
bit7 
bit6 
bit5 
bit4 
bit3 
bit2 
bit1 
bit0 
 
Reserved 
GSTOP 
GSCLR 
Initial value 
Attribute 
R0,W0 
R0,W0 
R0,W0 
R0,W0 
R0,W0 
R0,W0 
R0,W 
R0,W 
 
[bit7 to bit2] Reserved 
Always write 0 to these bits. 
 
[bit1] GSTOP: Simultaneous timer enable bit 
GSTOP 
Function 
Read 
Write 
0 is always read out. 
Enable the counting simultaneously. 
(Start the counting) 
Disable the counting simultaneously. 
(Stop the counting) 
 
 
This bit is used to simultaneously start/stop the counting of the free-run timer specified by the timer 
synchronous activation enable register (TCGSE). 
 
When this bit is set to "0": 
Start the counting of the 16-bit free-run timer of the free-run timer specified by the timer synchronous 
activation enable register (TCGSE). At this time, the STOP bit of the timer state control register (TCCS) 
of the free-run timer specified by the timer synchronous activation enable register (TCGSE) will be 
cleared to "0". 
 
When this bit is set to "1": 
Stop the counting of the 16-bit free-run timer of the free-run timer specified by the timer synchronous 
activation enable register (TCGSE). At this time, the STOP bit of the timer state control register (TCCS) 
of the free-run timer specified by the timer synchronous activation enable register (TCGSE) will be set 
to "1". 
 
The value read out is always "0". 
 
 
MB91520 Series
MN705-00010-1v0-E
916