Symmetricom 1100 User Manual

Page of 224
Chapter 4 Provisioning the TimeProvider
Provisioning the Input Reference
108  TimeProvider User’s Guide
097-58001-02 Revision G – April 2008
Provisioning the Input Reference
You need to know the following information about the input reference signal before 
you can provision the Input Reference signals:
Input selection mode
Interface type
Frame type/frequency
Quality level
Priority level
SSMs and bit position
CRC
Setting the Input State
Use the ED-EQPT command to provision the inputs to the TimeProvider. You can 
enable, disable, or place an input in Monitor mode (where the input is monitored, but 
cannot be selected as the system reference).
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
Sample Command
ED-EQPT::INP1:TS1000::INSTATE=MONITOR;
This command places Input 1 in the Monitor mode.
Autonomous Message
TP-SSU 03-10-24 10:44:21
A 1178 REPT EVT
“INP1,T1:NA,INSTATE,NSA,03-10-24 10-44-21:\"INPUT STATE 
HAS CHANGED,MONITOR\””
;
<aid>
<keyword>
<value>
Description
Default value
PRS
INPp (p = 1 | 2)
GPS
INSTATE
ENABLE
Enables the specified input
ENABLE
GPS = DISABLE
MONITOR
Places the specified input in 
Monitor Only mode
DISABLE
Disables the specified input