SETTING
THE
RELAYS
ENTER
This section sets up the relay information.
Press the PRGM key to choose A TOT (A
assigned to total) or A RATE (A assigned to
rate).  Press ENTER when the desired choice
is displayed.
This is the duration (.1 to 99.9 sec) that relay
A will remain energized.  If 00.0 is selected,
the relay will latch until reset.
Press the PRGM key to choose B TOT (B
assigned to total) or B RATE (B assigned to
rate).  Press ENTER when the desired choice
is displayed.
This is the duration (.1 to 99.9 sec) that relay
B will remain energized.  If 00.0 is selected,
the relay will latch until reset.
PRE A = Preset A (Final Preset); The set point
at which output A will trigger.  If the displayed
value is not  the desired preset, press the
key(s) under the digit to be changed.
PRE B = Preset B (Prewarn); The set point at
which output B will trigger.  If the displayed
value is not  the desired preset, press the
key(s) under the digit to be changed.
ENTER
factor
count
rate
loc
relay
 a tot
or
a rate
A ##.#
 b tot
or
b rate
b ##.#
PRE A
Followed by
last PRE A
entered
PRE B
Followed by
last PRE A
entered
ENTER
ENTER
SETTING
THE
PRESETS
PRE A
PRE B
This step will only
appear on DPF75
This step will only