Terminal 
Symbol 
Terminal Function 
Factory Settings (NPN mode) 
ON: Connect to GND 
M4 
Multi-function input 4 
M5 
Multi-function Input 5 
 
+17V 
DC Voltage Source  
+17VDC, 20mA used for PNP mode. 
GND 
Digital Signal Common 
Common for digital inputs and used for NPN 
mode. 
AFM 
Analog output meter 
Internal Circuit
AFM circuit
AFM
GND
0~10V
Max. 2mA
ondometer
 
RA 
Multi-function Relay output 
(N.O.) a 
RB 
Multi-function Relay output 
(N.C.) b 
RC 
Multi-function Relay common
Resistive Load: 
5A(N.O.)/3A(N.C.) 240VAC 
5A(N.O.)/3A(N.C.) 24VDC 
Inductive Load: 
1.5A(N.O.)/0.5A(N.C.) 240VAC 
1.5A(N.O.)/0.5A(N.C.) 24VDC 
Refer to Pr.3-06 for programming 
MO1 
Multi-function Output 1 
(Photocoupler) 
Maximum 48VDC, 50mA 
Refer to Pr.3-01 for programming 
MO1-DCM
Mo1
MCM
M ax: 48Vdc
         50mA
internal circuit
 
MCM Multi-function output common Max. 48Vdc 50mA 
+10V 
Potentiometer power supply 
+10VDC 10mA (variable resistor: 3~5kohm)