8.5.1 
Configuring Rate Limit 
To set a port bandwidth, use the following command. 
Command Mode 
Description 
rate
  PORTS RATE  [egress | in-
gress
Sets port bandwidth. If you input egress or ingress, you 
can configure outgoing packet or incoming packet. The 
unit is 64 Kbps. 
no rate
 PORTS 
Clears rate configuration of a specific port. 
no rate
 PORTS [egress | ingress]
Bridge 
Clears rate configuration of a specific port by transmit-
ting direction. 
 
Unless you input neither egress nor ingress, they are configured to be same. To switch, 
egress is incoming packet. To display the configured bandwidth, use the following com-
mand. 
Command Mode 
Description 
show rate 
Global 
Shows the configured bandwidth. 
 
8.5.2 Sample 
Configuration 
The following is an example of showing the configuration after setting the bandwidth of 
64Mbps to port number 1 and 128Mbps to the port number 2. 
SWTICH(bridge)# rate 1 64 
SWTICH(bridge)# rate 2 128 
SWTICH(bridge)# show rate 
 unit : kbps E : Enhanced 
------------------------------------------------------------------------------ 
Port  |    Ingress   |     Egress    |  Port  |    Ingress   |     Egress 
------------------------------------------+----------------------------------- 
   1  |        64     |         64     |   2  |       128     |       128 
   3  |       N/A     |       N/A      |   4  |       N/A     |       N/A 
   5  |       N/A     |       N/A      |   6  |       N/A     |       N/A 
   7  |       N/A     |       N/A      |   8  |       N/A     |       N/A 
SWTICH(bridge)#