6.1.12.4 System 
Temperature 
To set a threshold of system temperature, use the following command. 
Command Mode 
Description 
threshold temp
 VALUE VALUE 
Sets a threshold of system temperature in the unit of 
centigrade (°C). 
VALUE: Threshold temperature between -40 ~ 100  
no threshold temp 
Global 
Deletes a configured threshold of system temperature.
 
To show a configured threshold of system temperature, use the following command. 
Command Mode 
Description 
show status temp 
Enable 
Global 
Shows a status and configured threshold of system 
temperature. 
 
6.1.12.5 System 
Memory 
To set a threshold of system memory in use, use the following command. 
Command Mode 
Description 
threshold memory
 <20-100> 
Sets a threshold of system memory in the unit of per-
cent (%). 
20-100: system memory in use 
no threshold memory 
Global 
Deletes a configured threshold of system memory. 
 
6.1.13 
Enabling FTP Server 
FTP server is enabled on hiD 6615 S223/S323 by default. But this configuration can’t 
provide the security serveice becaue it’s easy to access to the port #23 by others. If the 
default configuration is unnecessary on sysem, user can disable the system as FTP 
server.  
To enable/disable the system of hiD S223/S323 as FTP server, use the following com-
mand. 
Command Mode 
Description 
ftp server 
{enabledisable} Global 
Enables/ disables the function for FTP serve 
Default: enable 
 
The follwing is an example of displaying the status of FTP server. 
SWITCH(config)# ftp server disable 
SWITCH(config)# show running-config 
(Omitted) 
ftp server disable 
(Omitted) 
SWTICH(config)#