 - ENGLISH
Settings
PROJECTOR SETUP menu
See 
 
z
(
Æ
page 39).
See 
 
z
(
Æ
page 40).
PROJECTOR ID
The projector has an ID number setting function that 
helps the user to control two or more projectors either 
simultaneously or separately with a single remote 
control.
Press ▲▼ to select [PROJECTOR ID].
1 ) 
Press ◄► to switch [PROJECTOR ID].
2 ) 
The setting will change as follows each time 
 
z
◄► is pressed.
ALL
1
6
2
Note
The ID number can be set to [ALL], or selected from [1] 
 
z
to [6].
If the projectors are given ID numbers, their remote 
 
z
controls must be assigned the same ID numbers, 
respectively.
If the ID number of a projector is set to [ALL], it can be 
 
z
controlled by the remote control or the PC with any ID 
number.
If multiple projectors are used and some of them 
have their IDs set to “ALL”, they cannot be controlled 
separately from the projectors with other ID numbers. 
For details on remote control ID setting, refer to “Setting 
projector ID number to remote control” (
Æ
page 21).
INSTALLATION
A projection scheme can be chosen depending on 
the installation of the projector. If the picture is shown 
upside down or in reverse, change the projection 
scheme.
Select the setting by displaying the on-screen 
 
z
indications using buttons of the remote control or 
the control panel on the main unit.
Press ▲▼ to select [INSTALLATION].
1 ) 
Press ◄► to switch [INSTALLATION].
2 ) 
The setting will change as follows each time 
 
z
◄► is pressed.
FRONT/FLOOR
FRONT/CEILING
REAR/CEILING
REAR/FLOOR
FRONT/ 
FLOOR
Setting on a desk/floor and 
projecting from front
FRONT/ 
CEILING
Mounting on the ceiling and 
projecting from front
REAR/ 
FLOOR
Setting on a desk/floor and 
projecting from rear
REAR/ 
CEILING
Mounting on the ceiling and 
projecting from rear
COOLING CONDITION
You can control the fan speed for projecting 
angle. When the projector is angled, [COOLING 
CONDITION] setting must be set correctly. Failure to 
observe this may result in malfunctions, or the life of 
the lamp or the other components may be shortened.
Press ▲▼ to select [COOLING 
1 ) 
CONDITION].
Press <ENTER> button.
2 ) 
The [COOLING CONDITION] screen will be 
 
z
displayed.
Press ▲▼ to select cooling condition.
3 ) 
Press <ENTER> button.
4 ) 
When the confirmation message is 
5 ) 
displayed, select [OK] or [CANCEL].
CEILING  
SETTING
30°
30°
VERTICAL DOWN 
SETTING
30°
30°
VERTICAL UP  
SETTING
FLOOR  
SETTING