Pelco C1528M-F User Manual

Page of 106
C1528M-F (6/05)
73
Appendix
CM6800E DIP SWITCHES
Figure 52.  CM6800E DIP Switches – Factory Default Settings
Table G.  CM6800E DIP Switch Settings
CM6800E DIP Switch
Default Setting
Switch 1 
OFF (0) = NTSC
ON (1) = PAL
CM6800E-48X8: OFF
CM6800E-48X8-X: ON
Switch 2 
RESERVED – must be in the OFF position for proper operation
OFF
Switch 3 
RESERVED – must be in the OFF position for proper operation
OFF
Switch 4 
RESERVED – must be in the ON position for proper operation
ON
Switch 5
RESERVED – must be in the OFF position for proper operation
OFF
Switch 6 
RESERVED – must be in the OFF position for proper operation
OFF
Switch 7 
USED TO RESET SOFTWARE. REFER TO THE SOFTWARE RESET SECTION.
CAUTION:  Resetting the software restores the system software to 
original settings, programmed by Pelco. All user programming is lost.
OFF
Switch 8 
RESERVED – must be in the OFF position for proper operation
OFF