ALARM GROUP DISPLAY OPTIONS
To display on a monitor, an alarm must be assigned to an alarm group (A-H). Before programming alarms you may want to determine the alarm 
display format for each alarm group. An alarm can include up to eight steps, so eight camera views could display as a part of each alarm.
A priority alarm appears on system monitors before non-priority alarms, despite the order specified by the alarm group assignment. In the 
examples below, all alarms are at the same priority level. Refer to the PRIORITY description in Program Internal and External Alarms.
BLOCK BUILD 
Alarmed cameras are displayed across a block of alarm monitors in a sequential order. All steps programmed for the alarm contact appear on the 
designated monitor.
Example: Eight alarms set to display on monitors 02-07 will appear in the following order:
New alarms display on the lowest monitor number with the fewest alarms cycling. 
CHRONOLOGICAL PAIR: D AND Q
The oldest alarm of a specific group is displayed on one designated monitor, while all other alarms in the group are sequenced on the second 
designated monitor. All steps programmed for the alarm contact appear on the designated monitor.
Example: Four alarms set to display on monitors 04 and 05 will appear in the following order:
You must acknowledge alarms in a chronological pair from the display monitor (D). Then the 
next oldest alarm moves to the display monitor and the remaining alarms continue to cycle 
through the queue monitor (Q). This format requires you to acknowledge each alarm in the 
order in which they occur.
Acknowledging alarms in this example:
Monitor
1st Display
Cycle
Next Display
Cycle
Acknowledging
Alarms 1 & 2
Next Display
Cycle
02 B
1st alarm
1st and 7th 
alarms cycle
Acknowledge
1st alarm
7th alarm
03 B
2nd alarm 
2nd and 8th 
alarms cycle
Acknowledge 
2nd alarm
8th alarm
04 B
3rd alarm
3rd alarm
3rd alarm
3rd alarm
05 B
4th alarm
4th alarm
4th alarm
4th alarm
06 B
5th alarm
5th alarm
5th alarm
5th alarm
07 B
6th alarm
6th alarm
6th alarm
6th alarm
Monitor
1 Alarm
2 Alarms
3 Alarms
4 Alarms
04 D
1st alarm
1st alarm
1st alarm
1st alarm
05 Q
2nd alarm 
2nd and 3rd 
alarms cycle
2nd, 3rd, and 4th
alarms cycle
Monitor
1st Cycle
Next Cycle
Next Cycle
Next Cycle
04 D
Acknowledge
1st alarm
Acknowledge 
2nd alarm
Acknowledge 
3rd alarm
Acknowledge 
4th alarm
05 Q
2nd, 3rd, and 4th 
alarms cycle
3rd and 4th 
alarms cycle
4th alarm
 
ALARM MONITOR GROUP SETUP
 
MON A 
H
 
01  – – – – – – – –
 
02  B – – – – – – –
 
03  B – – – – – – –
 
04  B – – – – – – –
 
05  B – – – – – – –
 
06  B – – – – – – –
 
07  B – – – – – – –
 
08  – – – – – – – –
 
HELP
 
00638
 
ALARM MONITOR GROUP SETUP
 
MON A 
H
 
01  – – – – – – – –
 
02  – – – – – – – –
 
03  – – – – – – – –
 
04 
– D – –  – – – –
 
05 
– Q – –  – – – –
 
06  – – – – – – – –
 
07  – – – – – – – –
 
08  – – – – – – – –
 
HELP
 
00640