Pelco C1528M-F User Manual

Page of 106
C1528M-F (6/05)
75
REVERSE CHRONOLOGICAL PAIR: M AND L
The most recent alarm of a specific group is displayed on one designated monitor, while all other alarms in the group are sequenced on the 
second designated monitor. All steps programmed for the alarm contact appear on the designated monitor.
Example: Four alarms set to display on monitors 06 and 07 will appear in the following order:
You must acknowledge alarms in a reverse chronological pair from the display monitor (M). 
Then the next most recent alarm moves to the display monitor and the remaining alarms 
continue to cycle through the queue monitor (L). This format requires you to acknowledge each 
alarm in the reverse order from which they occurred.
Acknowledging alarms in this example:
SALVO GROUP
Multiple camera views within the alarm contact programming (the “steps”) are displayed simultaneously as a group across a set of monitors. 
When a new alarm triggers, all monitors switch to the new alarm at the same time.
When programming a Salvo Group:
Program the Salvo Group to display across a number of monitors equal to the number of steps in the alarm contact(s); for example if the 
alarm contact has six steps, set the Salvo Group to display on six monitors. If an alarm contact contains more steps than monitors defined 
for the Salvo Group, the additional steps do not appear on a monitor during the alarm.
Each alarm contact assigned to the Salvo Group should contain the same number of steps.
The Salvo Group switches based on the dwell time entered for the first step in the alarm contact.
Example: Two alarm contacts with three steps display on three monitors will appear as follows:
Monitor
1 Alarm
2 Alarms
3 Alarms
4 Alarms
06 M
1st alarm
2nd alarm
3rd alarm
1st alarm
07 L
1st alarm
1st and 2nd 
alarms cycle
1st, 2nd, and 3rd 
alarms cycle
Monitor
1st Cycle
Next Cycle
Next Cycle
Next Cycle
06 M
Acknowledge 
Alarm 4
Acknowledge 
Alarm 3
Acknowledge 
Alarm 2
Acknowledge 
Alarm 1
07 L
Alarms 1, 2, 
and 3 cycle
Alarms 1 and 2 
cycle
Alarms 1
Monitor
1 Alarm
2 Alarms
Next Display 
Cycle
After 
Acknowledging 
1st Alarm
06 S
1st alarm, step 1
2nd alarm, step 1
1st alarm, step 1
2nd alarm, step 1
07 S
1st alarm, step 2
2nd alarm, step 2
1st alarm, step 2
2nd alarm, step 2
08 S
1st alarm, step 3
2nd alarm, step 3
1st alarm, step 3
2nd alarm, step 3
 
ALARM MONITOR GROUP SETUP
 
MON A 
H
 
01  – – – – – – – –
 
02  – – – – – – – –
 
03  – – – – – – – –
 
04  – – – – – – – –
 
05  – – – – – – – –
 
06 – 
– 
– 
– 
– 
– 
 
07  – – L – – – – –
 
08  – – – – – – – –
 
HELP
 
00641
 
ALARM MONITOR GROUP SETUP
 
MON A 
H
 
01  – – – – – – – –
 
02  – – – – – – – –
 
03  – – – – – – – –
 
04  – – – – – – – –
 
05  – – – – – – – –
 
06 – 
– 
– 
– 
– 
– 
 
07 – 
– 
– 
– 
– 
– 
 
08 – 
– 
– 
– 
– 
– 
 
HELP
 
00639