Silex Technology SX-500-1402 User Manual
Chapter 5
Advanced Configuration
The Serial Device Server Serial Device Server is equipped with a default configuration that works with
most serial-to-Ethernet connections. You can modify the settings to suit your installation requirements.
most serial-to-Ethernet connections. You can modify the settings to suit your installation requirements.
The web browser interface is the recommended method for setting advanced configuration parameters.
However, regardless of the method to access the configuration parameters, the method for modifying the
parameters is virtually identical.
However, regardless of the method to access the configuration parameters, the method for modifying the
parameters is virtually identical.
Factory Default Settings
Table 3 displays the serial port configuration parameter descriptions and settings with the default settings
indicated in a separate column.
indicated in a separate column.
Table 3 Factory Default Settings
Parameter
Description
Settings
Default Setting
Character
Bits per character
7, 8
8
Flow
Flow control
None, XON, XOFF,
CTS/RTS
CTS/RTS
None
Parity
Parity
None, Even, Odd,
Mark, Space
Mark, Space
None
Speed
Baud rate of bits per second
300, 600,1200, 2400,
3600, 4800, 7200,
9600, 14400,19200,
38400, 57600, 76800,
115200, 230400,
460800, 921600
3600, 4800, 7200,
9600, 14400,19200,
38400, 57600, 76800,
115200, 230400,
460800, 921600
115200
Stop
Stop bits per character
1, 2
1
Ecaddr
ECable destination IP address
Set by user
N/A
Econn
ECable connection attempt time
1-255 seconds
30 seconds
Ecport
ECable destination TCP port number
Set by user
N/A
Eclport
ECable destination local IP port
Set by user
N/A
Page 26
Silex
Advanced Configuration
Part Number 140-00188-210A