2.
Verify the settings, as defined in Table 4.
Table 4  TCP/IP Settings
Parameter
Setting
IP Address 
To assign a static IP address, enter it in this field 
The IP address must follow the format XXX.XXX.XXX.XXX, where 
each XXX is a number between 0 and 255. The default IP address 
mask is 192.0.0.192.
Subnet Mask
To assign a static subnet mask, enter it in this field
The subnet mask must follow the format XXX.XXX.XXX.XXX, where 
each XXX is a number between 0 and 255. The default subnet 
mask is 0.0.0.0. The server interprets a subnet mask of 0.0.0.0 or 
255.255.255.255 as no subnet mask specified. 
Default Gateway
Sets the default gateway, if your network is attached to other 
networks
Boot Method 
Set to STATIC for a static IP address, set to DHCP or AUTO to 
attempt to automatically assign the IP parameters from a network 
server.
TCP  Timeout
Sets the timeout and reset values for the TCP connections
Keepalive Timer
Blocks or broadcasts unsolicited ARP used to notify access point or 
router that the unit is still connected.
DNS
Sets the DNS addresses
3.
For the changes to become effective, click the Submit button, then reset the Serial Device Server. 
Using AT Modem Commands
NOTE: The AT Command filter cannot be used in a FIPS 140-2 approved mode.  The Cryptographic 
Officer must leave the port filter setting as TRAP (the factory default value).
The Serial Device Server firmware has an optional data filter for configuring using AT style modem 
commands with the serial port.  This feature allows devices with an existing AT command interface to 
configure the unit, if the AT commands can be properly modified.   You must be familiar with the general 
operation of AT commands. Note that AT command processing is not enabled by default. Use the 
command SET PORT S1 FILTER AT to enable this feature.
All commands begin with AT and are terminated by a new line unless noted below.  While standard AT 
commands are defined to be 40 characters or less (not including the AT), the server accepts commands 
of up to 80 characters.
Page 28
Silex
Advanced Configuration 
Part Number 140-00188-210A