Nortel Networks 555-4001-135 User Manual

Page of 244
220   Upgrades
553-3001-358/555-4001-135   Standard   02.00   July 2006  
Procedure 47  
 
Firmware upgrade using FTP
1
Click on the FTP Server radio button.
2
Enter the FTP parameters in the fields the window provides as follows:
a
IP address – the remote FTP server where the upgrade files are stored.
b
Path  to  file  – path of the folder on the computer where the upgrade files 
are stored (for example, c:\ICB\4_01).
c
Login – login name for FTP.
d
Password – password for FTP login.
3
Click on the Get Files button to start the FTP transfer session.
4
After the previous steps finishes, click on the Upgrade & Restart button.
 
 
The ICB copies the files from the FTP server and performs a restart. When 
the restart is complete, the current BUI session is lost. Login again as an 
administrator. When returning to this window, the new firmware version 
This procedure is now complete
should appear in the top-right corner of the window.
Upgrade to the single DN access method
Follow the steps in Procedure 48 to upgrade an existing MICB Release 
2 or MICB Release 3 card to ICB Release 4 configured with single DN 
access.
Procedure 48  
 
Upgrade to single DN access
1
Follow 
 to upgrade an MICB Release 2 or MICB 
Release 3 card to an ICB Release 4 card.
2
Configure the DNs.
a
Remove the DN pairs from the switch datafill. For more information, if 
your system is a Meridian 1 or CS 1000, see 
; if your system is a CS 2100 or Meridian SL-100 see 
.
Note:  DN pairs can be left in the ICB. Callers to existing conferences 
configured with direct access DNs will be requested to enter the access DN to 
reach the meeting.
b
Configure the single access DN in the switch. For more information, if 
your system is a Meridian 1 or CS 1000, see 
; if your system is a CS 2100 or Meridian SL-100 see 
.
Note:  This DN should be forwarded to the ICB card main ACD DN.
3
Access the ICB Installation Wizard and perform the following (see 
a
Click on the first radio button for the single DN access method.
b
Enter the new single-access DN.