Nortel Networks 555-4001-135 User Manual

Page of 244
Installation and configuration   57
Nortel Integrated Conference Bridge Service Implementation Guide
3
Define the ICB conference and chairperson bridge DNs. Refer to 
. This step provides the following:
a
Main DN for conference ACD groups to access the ICB agents on the 
card. 
b
Conference DNs and Chairperson DNs.
c
TUI DN and Assistant DN. 
d
Single number access conference and chairperson DN.
4
Define the night service route from ACDGRP NSROUTE.
 
 
The night service DN assigned in table OFRT allows conference and 
chairperson ACDGRPs to route to the ICB card ACD agents. Table 
DNROUTE defines the routes. 
 shows an example of 
table OFRT routing to 214 997 1400 (ICB DN) assigned in table DNROUTE.
5
Use the following tables and command interfaces (CIs) to datafill the ICB for 
single-card configuration:
Table LNINV.
Table ACDGRP.
Table ACDSGRP.
Table ACDLOGIN.
Table CUSTACD (optional).
Table ACDENLOG (optional).
Table DNROUTE.
Table  OFRT.
Table OFCENG.
Service Orders.
Figure 12  
 
LNINV example
Note:  Cardcode can also be configured as an 8D02 digital line card.
Figure 13  
 
ACDGRP example
LEN CARDCODE PADGRP STATUS GND BNV MNO CARDINFO
----------------------------------------------------------------------------------------
IPE1 00 0 00 00 5D51AB NPDGP WORKING N NL Y FLXA
ACDNAME CUSTGRP ACDRNGTH THROUTE NSROUTE PRIOPRO DBG 
MAXCQSIZ MAXWAIT ACDMIS MSQS DISTRING OBSWTONE FRCNGTSV 
OPTIONS
----------------------------------------------------------------------------
MICB BNRRCH 12 OFRT 600 OFRT 600 0 Y 2 0 N N NONE N N (ACDDISP 4) 
(NONIMCUT ) $