Genie 3062m3064 User Manual

Page of 24
8
Wall Control Operation
Force Control
The force controls are automatically set when the wall control is used 
for the first time with garage door opener. The door MUST complete 
one full cycle, from full open to full close and then, full close to full 
open, before the settings are automatically recorded.
Contact Reverse Test
NOTE: The limit and Force settings MUST BE COMPLETED before 
performing the Contact Reverse Test.
When the door contacts the board, it should stop and reverse  
direction within 2 seconds to the fully open position. Long LED 
light on the powerhead will begin to flash RED with the reversal 
of the door. Remove the 2" x 4" board after a successful contact 
reversal test. The next cycle will clear the flashing red LEDs.
Contact Reverse Adjustment
If the door stops before contacting the board or if it does not 
reverse direction to fully open after contact with the board, it 
may be due to an improperly set DOWN limit. Verify settings by:
1.  Repeat the “Down Travel Limit” section (page 6) to make 
certain the door is closing tight against the floor.
2.  Repeat the “Force Control” section on the left to set force 
limits.
3.  Repeat the “Contact Reverse Test” above.
Repeat this process as needed until the door passes the Contact  
Reverse Test. For further help, refer to the “Maintenance and 
Adjustment” section/Regular Maintenance. (Pages 14-18).
NOTE: Force controls DO NOT require programming. Force limits are factory 
set and rarely require adjustments. Making adjustments to these settings is 
covered in the “Maintenance and Adjustments” Section of this Manual (pages 
14-18). FORCE CONTROL IS NOW SET.
12.  With the garage door open, lay a 2” x 4” board flat on   
 
the floor at the center of the door opening.
11.  Press and release the wall console Open/Close button   
 
and allow your garage door to travel and stop at the up  
 
(open) limit.
10. Press and release the wall console Open/Close button   
 
and allow the garage door to travel and stop at the   
 
down (closed) limit.
13.  Close the garage door using the Open/Close button on  
 
the wall control.
WARNING
!
TO AVOID INJURY OR DAMAGE
NEVER adjust the force settings to adjust for damage,   
including an unbalanced door, binding door track or    
broken spring.
Perform a CONTACT REVERSE TEST monthly. 
AVERTISSEMENT
!
Pour éviter les blessures ou des dommages
NE JAMAIS régler la force pour compenser des dommages, 
y compris une porte mal équilibrée, un rail de porte coinçant 
ou des ressorts cassés.
Tous les mois, EFFECTUEZ LE TEST D’INVERSION AU CONTACT.