Genie 3062m3064 User Manual

Page of 24
6
Programming Information
TRAVEL LIMITS
NOTE: If carriage has NOT been engaged to carriage, do so now. 
Before setting limits: confirm wall console red indicator  
back light is ON. If not illuminated, See page 19 for troubleshooting.
Check STB LED’s: Confirm both LED’s are Illuminated solid. If not 
Illuminated solid, see page 18 for troubleshooting.
Closing Garage Door (Down Limit)
NOTE:
 Beginning with garage door in mid travel is recommended but not 
necessary.
WARNING
!
Make sure doorway is in full view and clear of obstacles and 
people to avoid injury or property damage.
DO NOT operate this unit from the wall control before LIMITS 
are set. Severe damage to the opener could occur.
The carriage MUST be engaged BEFORE setting limits. See 
installation poster (if provided) or call Customer Service at 
1-800-35-GENIE or visit www.GenieCompany.com.
AVERTISSEMENT
!
S’assurer que le passage de la porte est visible et dégagé, à 
savoir sans obstacles ni personne afin d’éviter toute blessure 
potentielle ou dommage matériel.
NE PAS utiliser cette unité avec la console murale avant 
d’avoir réglé les LIMITES. L’ouvre-porte pourrait subir de 
sérieux dommages.
La tendeur DOIT être engagée dans le chariot AVANT de 
régler les limites. Voir le poster d’installation (si fourni) ou 
appelez le service clientèle au 1-800-35-GENIE ou visitez le 
site www.GenieCompany.com.
NE PAS fixer de limites en mode batterie de secours. 
L’alimentation CA DOIT être branchée sur l’ouvre-porte, 
pendant le réglage des limites, pour assurer un bon 
fonctionnement.
PRGM
SET
PRGM
SET
PRGM
SET
PRGM
SET
READ AND UNDERSTAND STEPS 2-5 BEFORE 
PROCEEDING
2.  Press and hold the down arrow button (–) for two   
  seconds or until the long LED comes on blue. (The round  
  LED stays off.)
Steady Blue
3.  Release down arrow button (–) and the long LED will   
  begin flashing blue. (Round LED still off.)
Flashing Blue
5. Press and release the program/set button—both LEDs  
  flash blue and then go off.
 
The DOWN (CLOSED) TRAVEL LIMIT IS NOW PROGRAMMED.
Flashing 
Blue
4.  Press and hold the down arrow button (–) to begin   
  closing the garage door. When the garage door is fully   
  closed, release the down button (–). If it has gone too far  
  press and release the up button (+) to move the door   
  up slightly. The door can be moved  up or down with the  
  arrow buttons. The door should rest tightly on the floor.
1.  Lift door by hand until carriage engages the shuttle on 
screwdrive or the bullet on the chain/belt. 
Lever must be UP Lever must be UP
Screw
Drive
Chain/
Belt Drive