Wall Control Features
One of the following wall controls will be included.
NOTE: Wall consoles from other manufacturers may not work with this new opener. Use only the wall control provided with this unit. See warning.
SERIES II WALL CONSOLES
TYPE 1 FEATURES
Indicator Light
Large white button will display Red when wall console is properly  
wired and Sure-Lock™ is OFF. When Sure-Lock™ is ON, this light is off.
Open/Close Button
Use this button to open or close garage door. When Sure-Lock™ is  
ON the Open/Close button will CLOSE the door only.
NOTE: Constant button pressure in the CLOSE direction will  
override STB fault in the powerhead and close door.
Independent Light Control Button
Use this button to turn the powerhead lights ON. Powerhead lighting will 
remain ON until this button is pressed again or a door action has been 
completed.
Sure-Lock™ Button
When Sure-Lock™ is ON, and the door is closed, the powerhead cannot be 
activated by the wall console or a remote. 
• Press and release to activate Sure-Lock™ (red light goes off). 
• Press and release to turn Sure-Lock™ OFF (red light goes on).
WALL BUTTON
This is a lighted wall button. Press once to move 
the door. 
If the button is not lighted, check:
-White wire connected to terminal “W” 
-Striped wire connected to terminal “B”
Open/Close Button
Opens and closes door from inside garage.
Indicator Light
-Red indicator backlight is ON.
-When Sure-Lock™ in ON, indicator is off.
Sure-Lock™ Button
-LOCK disables controls after door is 
completely closed.
-UNLOCK allows controls to work normally.
Independent Light Control Button
Controls door opener lights from inside 
garage.
TYPE 2 FEATURES
Indicator Light
Large white button will display Red when wall console is properly  
wired and Sure-Lock™ is OFF. When Sure-Lock™ is ON, this light is off.
Open/Close Button
Use this button to open or close garage door. When Sure-Lock™ is  
ON the Open/Close button will CLOSE the door only.
NOTE: Constant button pressure in the CLOSE direction will  
override STB fault in the powerhead and close door.
Independent Light Control Button
Use this button to turn the powerhead lights ON. Powerhead lighting will 
remain ON until this button is pressed again or a door action has been 
completed.
Sure-Lock™ Button
When Sure-Lock™ is ON, and the door is closed, the powerhead cannot be 
activated by the wall console or a remote. 
• Slide switch up to activate Sure-Lock™ (red light goes off). 
• Slide switch down to turn Sure-Lock™ OFF (red light goes on).
TYPE 1
TYPE 2
WARNING
!
Use of any other wall control can cause unexpected 
operation of the door and loss of lighting feature. Locate 
wall console within sight of door but far enough from 
door to prevent contacting it while operating the console. 
Control must be at least 5 feet above the floor to prevent 
small children from operating it. 
AVERTISSEMENT
!
l’utilisation d’une autre commande murale pourrait des résultats 
in attendus de la porte ainsi que le dysfonctionnement de 
l’éclairage. Localisez la console murale en vue de la porte et 
suffisamment loin de la porte pour éviter tout contact pendant 
l’utilisation de la console. La commande doit être à une hauteur 
minimale de 1,5 m au-dessus du sol afin que les jeunes enfants ne 
puissent pas l’attiendre.