ETEMS Troubleshooting
224
EncrypTight User Guide
Appliance Unreachable 
Symptom
Explanation and possible solutions
Symptoms of ETEMS’s inability to 
communicate with an appliance are:
• Status indicator of 
?
.
• “Operation failed” result when 
putting a configuration to an 
appliance, refreshing status, or 
comparing configurations.
• Unsuccessful software upgrade.
• Check physical connectivity to the appliance’s management 
port (proper seating of the RJ-45 Ethernet cable).
• Verify that the management IP address is the same in 
ETEMS and on the appliance. Refresh the appliance status, 
and then compare configurations (Tools > Compare 
Config to Appliance). 
• The connection between ETEMS and the appliance has 
timed out. Check the timeout setting (Edit > Preferences
and adjust if necessary.
• Check for a password mismatch between the appliance and 
ETEMS. Refresh the appliance status, and then look at the 
resulting error message or ETEMS log for a failure 
description. If the message indicates an invalid password, 
update ETEMS with the appliance password. 
• If IPSec is enabled on the management port, disable it and 
then disable the IPSec client. Verify that you can 
communicate with the appliance when IPSec is disabled. If 
not, check the preceding items to resolve the problem. If 
you can successfully establish communication with IPSec 
disabled, ensure that the IPSec client configuration matches 
the appliance’s IPSec management port configuration. 
Enable IPSec on the management port and enable the 
IPSec client. If this does not fix the connectivity problem, 
see your system administrator or contact Customer 
Support. 
Unable to communicate with 
appliance via xml-rpc. Connection 
timed out. 
Possible causes are: 
• Appliance is unplugged or powered off.
• Appliance is rebooting.
• Communication timeout value is set too low (Edit > 
Preferences).
• When managing ETEPs, TLS must be enabled in ETEMS. 
To check the TLS setting, go to Edit > Preferences > 
ETEMS > Communications and select Use TLS for XML/
RPC. 
• When using trusted hosts on the ETEP, if you type the 
management station IP address incorrectly, EncrypTight will 
be unable to communicate with the ETEP. To recover, use 
SSh to log in to the CLI (Tools > Ssh). Log in as the ops 
or admin user, and at the command prompt type configure 
to enter configuration mode. From the config> prompt, 
type disable-trusted-hosts to disable the trusted hosts 
entries for the ETEP.
The appliance can communicate 
with the management station but is 
unable to respond to a request. 
The following error message may be 
displayed: Appliance returned 
an unknown status code [-
1].
• Retry the operation. The appliance may have been in a 
transitional state and is now up and operational.
• Connect to the appliance’s CLI. Check for messages that 
provide an indication of the appliance’s status.
• Reboot the appliance from the CLI. After the appliance has 
rebooted, refresh the status.
• If the above steps fail to clear the message, contact 
customer support.