Black Box ET0010A User Manual

Page of 352
Possible Problems and Solutions
EncrypTight User Guide
225
Appliance Configuration
The ETEP cannot ping the 
management workstation. 
The request times out or returns an 
“Operation not permitted” message.
Check whether the trusted host feature is enabled on the 
ETEP. 
• Check the configuration for the trusted workstation. Pings 
are not allowed when the ICMP is unchecked in the trusted 
host configuration. 
• You can disable trusted hosts from ETEMS or by issuing 
the disable-trusted-hosts CLI command.
Cannot access the ETEP 
management port using SSH. 
• Check the setting for the ssh-enable command. It must be 
set to true. 
• Enabling FIPS mode or strong password enforcement on 
the ETEP causes the SSH daemon to restart, closing all 
open SSH connections. After enabling either of these 
features, wait 30-60 seconds before trying to re-establish 
an SSH connection to the ETEP management port. 
• If you used SSH to manage the ETEP prior to replacing a 
certificate or entering FIPS mode, you may not be able to 
establish an SSH session after the configuration change. 
To correct this, clear the known host entry for your SSH 
client and retry.
Symptom
Explanation and possible solutions
Can’t change the management port 
IP address on the appliance from 
ETEMS.
• The management port IP address must be unique. In the 
Appliances view, check for duplication.
• Verify that the appliance’s management port is not in use 
by a CLI session or the appliance web interface.
Editing the management IP address 
or date returns a 
 status.
• Refresh the appliance status. 
• If the refreshed status is still not equal, compare the 
ETEMS and appliance configurations (Tools > Compare 
Config to Appliance) to determine which items are 
different. Make any necessary adjustments to synchronize 
the two configurations.
Appliance setting is not displayed as 
a configuration option in ETEMS. 
• Not all features are supported in each appliance model or 
software revision. Check the model number and software 
version configured for the appliance, then refer to the 
Factory Default tables in the configuration chapter for your 
appliance model to check feature availability.
When configuring a new appliance, 
changing the product family 
(appliance model) causes other 
configuration settings to be 
discarded.
• To carry configurations forward when changing the product 
family, save the configuration prior to changing the product 
family.
Can’t change the appliance date or 
time from ETEMS.
• When the SNTP client is enabled on the appliance, you 
cannot change the appliance date or time. To modify the 
date or time, disable SNTP, push the configuration to the 
appliance, and then set the date (Edit > Date).
Symptom