Removal and Replacement::
1.  Remove the wires from the switch terminals.
2.  Compress the clips inside the autofill box and 
gently push the switch through the opening
3.  Push the new switch into the opening and spread 
the clips to hold switch in the autofill box.
4.  Refer to Fig 7 when reconnecting the wires.
P1522
FIG. 7 MAIN ON/OFF SWITCH TERMINALS
BLK from Fuse Holder
BLK to Pump Switch #2
MAIN ON/OFF SWITCH
FIG. 6 MAIN ON/OFF SWITCH
P1561
Location:
 
The main ON/OFF switch is located on the 
lower right front of the autofill box just above the 
power cord.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Disconnect  the black wire from the fuse holder 
to the main  ON/OFF switch. Disconnect the white 
wire from pump #1.
3.  Check for voltage across the black wires removed 
from the switch and the white wire removed from 
pump #1. Connect the dispenser to the power 
source. The indication must be:
 
a) 120 volts ac for 2 wire 120 volt models.
 
b) 200 to 240 volts ac for two wire 200 or 240 volt 
models.
4.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the wir-
ing diagrams and check the dispenser wiring harness.
5.  Check for continuity across the switch terminals 
with the switch in the “ON” position. Continuity 
must not be present when the switch is in the 
“OFF” position.
If continuity is present as described, reconnect the 
wires to the switch terminals.
If continuity is not present as described, replace the 
switch.
28791.1 011500
SERVICE (cont.)