4. Controls and Adjustments
CAUTION
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact
Hoshizaki Technical Support at 1-800-233-1940.
a) Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions:
S4 Dip Switch 
S4 Dip Switch No.
1
2
3
4
5
6
7
8
9
10
KM-2500SWH3
OFF OFF OFF OFF OFF OFF OFF OFF OFF ON
KM-2500SRH3
OFF OFF OFF OFF OFF OFF OFF OFF OFF ON
b) Harvest Timer (S4 dip switch 1 & 2)
The harvest timer starts when the thermistor warms to 48°F (9°C) at the evaporator 
outlet and the control board reads the thermistor's 3.9 kΩ signal. The harvest timer is 
factory set, and generally no adjustment is required. However, a setting longer than the 
factory setting may be advised in cases where the flush provided at harvest needs to be 
prolonged for extra cleaning. Before changing this setting, contact Hoshizaki Technical 
Support at 1-800-233-1940 for recommendations. Keep in mind that setting the harvest 
timer to a longer setting will decrease 24 hour production.
Note that the pump-out timer (S1 dip switch 3 & 4) acts in place of the harvest timer
during cycles with a pump-out. For details, see "II.C.4.c) Pump-Out Timer (S1 dip
switch 3 & 4)."
S4 Dip Switch Setting
Time 
(seconds)
No. 1
No. 2
OFF
OFF
60
ON
OFF
90
OFF
ON
120
ON
ON
180
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5 & 6)
Pump-Out Timer (3 & 4)
Harvest Timer (1 & 2)
Bin Control Selector (7)
Factory Use (8)