c) Pump-Out Timer (S4 dip switch 3 & 4)
When a pump-out is called for, the pump motor stops after the preceding freeze cycle. 
The pump motor energizes 2 seconds later in the reverse direction, taking water from 
the bottom of the tank and forcing pressure against the check valve seat allowing water 
to go through the check valve and down the drain. At the same time, water flows through 
the small float switch tube to power flush the float switch. The pump motor drains the 
water tank for the time determined by the pump-out timer. The pump-out timer also acts 
in place of the harvest timer during cycles with a pump-out. The pump-out timer is factory 
set, and generally no adjustment is required. However, where water quality is bad and 
the icemaker needs a longer pump-out time, the pump-out timer can be adjusted. The 
pump-out timer control can be set to pump-out for 10 or 20 seconds. 
S4 Dip Switch Setting
Time (seconds)
Inlet 
Water 
Valve
No. 3
No. 4
T1
T2
OFF
OFF
10
150
closed
ON
OFF
10
180
closed
OFF
ON
10
120
open
ON
ON
20
180
closed
T1: Time to drain the water tank
T2: Harvest timer at pump-out
d) Pump-Out Frequency Control (S4 dip switch 5 & 6)
The pump-out frequency control is factory set to drain the water tank every cycle, and 
generally no adjustment is required. The pump-out frequency control can be set to have 
a pump-out occur every cycle, or every 2, 5, or 10 cycles.
The first pump-out occurs after the 1st freeze cycle. 
S4 Dip Switch Setting
Frequency
No. 5
No. 6
OFF
OFF
every cycle
ON
OFF
every 2 cycles
OFF
ON
every 5 cycles
ON
ON