C2904M-B (2/05)
CONNECTING PELCONET TO A CM6700 AND KBD200A FOR REMOTE ASCII CONTROL
Refer to Figure 51. This configuration lets an operator view and control cameras with a remote KBD200A keyboard.
Figure 51.  Using PelcoNet with CM6700 and KBD200A to Provide Remote Control
Video In
Video Out
Audio Out
Audio In
COM1: RS232/485
Ethernet
Power
100-250VAC50/60Hz 100mA
COM2: RS232
10/100 Base-T
Video In
Video Out
Audio Out
Audio In
COM1: RS232/485 10/100 Base-T
Ethernet
Power
100-250VAC50/60Hz 100mA
COM2: RS232
PELCONET RECEIVER
PELCONET TRANSMITTER
PELCONET REMOTE KBD200A  ASCII MODE SETUP
GND 
PV130
TD(A)
TD(B)
RD(A)
RD(B)
GND
+12 VDC
RD(A) 
RD(B) 
TD(A) 
TD(B) 
12V 
PV130 ORDERED
SEPARATELY
2-RX
3-TX
5-GND
TRANSPARENT
DATA PORT
NOTE: FIRMWARE VER 4.0 OR LATER REQUIRED.
            SET KEYBOARD DIP SWITCHES - SWITCH
            6 ON, SWITCHES 5 AND 8 OFF, SWITCHES
            1 - 4 FOR ADDRESS ACCORDING TO THE
            TABLE IN THE KBD200A MANUAL.
KBD200A
RJ-45 WALL BLOCK AND STRAIGHT
CABLE SUPPLIED
TRANSPARENT DATA PORT
USING INTERNET EXPLORER, SET
TRANSPARENT DATA SETTINGS
ON BOTH PELCONET RECEIVER
AND TRANSMITTER:
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1
TO NETWORK
(LAN/WAN)
1   2   3   4   5   6   7   8
ON
1   2   3   4   5   6   7   8
ON
RS-422/485
ON
OFF
KEY
RS-232
SW5 DIP SWITCH SETTINGS
1
3
5
7
9
2
4
6
8
10
11
12
14
13
15
16
1
2
VIDEO INPUTS
VIDEO OUTPUTS
ALARMS
(1-9)
ALARMS
(10-18)
COM 1 (1-6)
COM 2 (7-12)
CONTROL
OUTPUTS
REMOTE KEYBOARD(S)
LOCAL
KEYBOARD
1  2   3   4   5  6   7   8   9
10 11 12 13 14 15 16 17 18
1  2   3   4   5  6   7   8   9 10 11 12
0 1 2 3
F
2
F
3
N
O
N
C
C
O
M
T T
R R
+
+
CM6700-MXB
SET DIP SWITCH (SW5) ON CM6700-MXB TO RS-232 MODE
PELCONET
TRANSPARENT
DATA PORT
2 RX......................
3 TX.....................
5 GND.....................
CM6700-MXB
COM 2 (7-12)
7  TX
12 RX
  9 GND
CM6700 MATRIX COM 2
PORT SETTINGS:
SPECTRA COAXITRON
PROTOCOL
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1
CONNECT PELCONET TO
6700 VIA RS-232 PORT
2-RX
3-TX
5-GND
TO NETWORK
(LAN/WAN)
12VAC