CONNECTING PELCONET TO A CM6700 ASCII PORT
Refer to Figure 52. This configuration lets an operator view and control cameras from a PC using a web browser. (The operator’s PC is not
shown on the diagram.)
Figure 52.  Using PelcoNet with CM6700 to Provide Remote Control
Video In
Video Out
Audio Out
Audio In
COM1: RS232/485 10/100 Base-T
Ethernet
Power
100-250VAC50/60Hz 100mA
COM2: RS232
PELCONET TRANSMITTER
TRANSPARENT
DATA PORT
TRANSPARENT DATA PORT
USING INTERNET EXPLORER, SET
TRANSPARENT DATA SETTINGS
ON BOTH PELCONET RECEIVER
AND TRANSMITTER:
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1
1   2   3   4   5   6   7   8
ON
1   2   3   4   5   6   7   8
ON
RS-422/485
ON
OFF
KEY
RS-232
SW5 DIP SWITCH SETTINGS
1
3
5
7
9
2
4
6
8
10
11
12
14
13
15
16
1
2
VIDEO INPUTS
VIDEO OUTPUTS
ALARMS
(1-9)
ALARMS
(10-18)
COM 1 (1-6)
COM 2 (7-12)
CONTROL
OUTPUTS
REMOTE KEYBOARD(S)
LOCAL
KEYBOARD
1  2   3   4   5  6   7   8   9
10 11 12 13 14 15 16 17 18
1  2   3   4   5  6   7   8   9 10 11 12
0 1 2 3
F
2
F
3
N
O
N
C
C
O
M
T T
R R
+
+
CM6700-MXB
SET DIP SWITCH (SW5) ON CM6700-MXB TO RS-232 MODE
CM6700 MATRIX COM 2
PORT SETTINGS:
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1
2-RX
3-TX
5-GND
TO NETWORK
(LAN/WAN)
PELCONET CM6700 ASCII SETUP SPECTRA COAXITRON    PROTOCOL
PELCONET
TRANSPARENT
DATA PORT
2 RX.......................
3 RX.....................
5 GND.....................
CM6700-MXB
COM 2 (7-12)
  7 TX
12 RX
  9 GND