Pelco C2904M-B User Manual

Page of 82
72
C2904M-B (2/05)
CONNECTING PELCONET TO A CM9760-DT FOR REMOTE BROWSER CONTROL
Refer to Figure 53. This configuration lets an operator view and control cameras on a PC using a web browser. (The
operator’s PC is not shown on the diagram.)
Figure 53.  Using PelcoNet with CM9760-DT to Provide Remote Control of a 9760 Monitor Output
Video In
Video Out
Audio Out
Audio In
COM1: RS232/485 10/100 Base-T
Ethernet
Power
100-250VAC50/60Hz 100mA
COM2: RS232
TRANSPARENT DATA PORT
CM9760-MXB 
USING INTERNET EXPLORER
SET TRANSPORT SETTINGS:
BAUD RATE
DATA BITS
PARITY
STOP BITS
VIDEO
SPECTRA “P”
PROTOCOL
CM9760-CC1 
CM9760-KBD CM9505-UPS 
PELCONET CM9760-DT SETUP
2-RX
3-TX
5-GND
CM9760-DT1 
12VAC
1 ON 
2 OFF
COM A
COM B
2-RX
3-TX
5-GND
NULL MODEM
CABLE NOT
SUPPLIED
SUPPLIED
CABLE
DIP SWITCH
COM 1
COM 2
COM 2 PROGRAMMED FOR 9760-DT
CAT 5 TO NETWORK
(LAN/WAN)
4800 OR 9600
8
EVEN OR ODD
1
PELCONET TRANSMITTER
NOTE: 4800 BAUD AND EVEN PARITY APPLIES TO CM9760-DT VERSION 2.07,
WHILE 9600 BAUD AND ODD PARITY APPLIES TO VERSION 3.0