Location
To meet NSF standards, all units must be sealed 
to the floor.
Be sure the location chosen has a floor strong enough 
to support the total weight of the cabinet and contents. 
Contents fully loaded in this product line can weigh as much 
as 1500 lbs.  Reinforce the floor as necessary to provide for 
maximum loading.
For the most efficient refrigeration, be sure to provide good 
air circulation inside and out. Do not pack the refrigerator so 
full that air cannot circulate. Be sure that the exterior of the 
unit has access to ample air. Avoid hot corners and locations 
near stoves and ovens.
Leveling
To level unit, simply lower the four adjustable rubber feet 
located under the unit to the floor and adjust until unit is 
level. A level cabinet will perform better because the drain 
will empty properly, the doors will line up with the frames 
correctly and the cabinet will not be subject to undue strain.
Plumbing
Self-contained models are standard with a condensate 
evaporator. If the evaporator fails, the unit’s drain must have 
an outlet to an appropriate drainage area or container.
Moisture collecting from improper drainage 
can create a slippery surface on the floor and 
a hazard to employees. It is the owner’s and 
operator’s responsibility to provide a container or 
outlet for drainage.
Electrical connection
Refer to the amperage data on page 3, the serial tag, your 
local code or the National Electrical Code to be sure the 
unit is connected to the proper power source. A protected 
circuit of the correct voltage and amperage must be run for 
connection of the line cord, or permanent connection to the 
unit.
Self-contained units have an ON/OFF switch located on 
the operators side. Simply turn the switch to ON to begin 
operation.
The power switch should be turned to OFF and the 
unit disconnected from the power source whenever 
performing service or maintenance functions.
CAUTION
On self-contained models, after turning the ON/OFF switch 
to ON, the unit’s compressor will begin operating. Delfield 
display cases are designed to maintain an operational 
temperature of 36°F to 40°F.
Do not load the storage area in a way that restricts the air 
flow. Overloading will result in the loss of temperature. Do 
not throw items into the storage area. The interior of the 
cabinet and the blower coil may be damaged by this type of 
neglect, which is not covered under your warranty.
These units use HFC-404A refrigerant, and 
have a lock-out high pressure limiting device. 
Under severe overloading conditions, in the 
event of a condenser fan failure or a plugged or 
blocked condenser, this device may shut down 
the refrigeration system. See page 17 for part number 
information if a replacement is required.
INSTALLATION: 500 CD, CR, CRR & OR
OPERATION: 500 CD, CR, CRR & OR