Adjustments 
Push Buttons 
TIMER TO CLOSE  
Adjusts time before gate automatically closes 
 
 
 
Adjustable 5 to 70 seconds. 
 
DUAL GATE DELAY  Adjusts delay between master and slave op-
 
 
 
eration 0-4 seconds (836 only for use with 
 
 
 
magnetic, solenoid, and other locking de 
   vices) 
 
CURRENT SENSITIVITY  
Increases or decreases the Auto Reverse 
   sensitivity. 
 
 
 
 
 
LED ENABLE   When depressed, activates LEDs for 15   
 
 
minutes to assist in installation and troubleshooting.  
 
 
 
 
 
Hold the push button down for five seconds to put 
 
 
the board in program mode. 
RESET  
Resets the microprocessor. Returns processor to  
  last 
known 
state. 
 
OPERATE  
When depressed, activates the gate. Used for initial 
  installation 
and 
testing. 
Hard Shutdown Reset  Resets the operator when the gate current 
 
 
 
senses twice before fully opening or closing.  
Jumpers 
STOP CIRCUIT JUMPER 
When the STOP CIRCUIT  
program switch #5 must be ON
  JUMPER is connected, the gate 
    will 
operate 
normally. 
 
 
 
 
  
STOP CIRCUIT JUMPER 
When a 3-button station is con-
program switch #5 must be OFF
 nected to the board, the STOP  
    CIRCUIT 
JUMPER 
must 
be 
re- 
 
 
 
 
moved.