Renesas R5S72621 User Manual

Page of 2152
 
Section 14   Realtime Clock 
 
 
Page 682 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
14.3.5
 
Day of Week Counter (RWKCNT) 
RWKCNT is used for setting/counting day of week section. The count operation is performed by a 
carry for each day of the date counter. 
The assignable range is from 0 through 6 (practically in BCD), otherwise operation errors occur. 
Carry out write processing after stopping the count operation through the setting of the START bit 
in RCR2. 
Undefined Undefined Undefined
0
1
2
3
4
5
6
7
0
R/W
R/W
R/W
R
0
R
BIt:
Initial value:
R/W:
-
-
0
R
-
0
R
-
0
R
-
Day
 
 
Bit Bit 
Name 
Initial 
Value R/W 
Description 
7 to 3 
 All 
Reserved 
These bits are always read as 0. The write value should 
always be 0. 
2 to 0 
Day 
Undefined  R/W 
Day-of-Week Counting 
Day-of-week is indicated with a binary code. 
000: Sunday 
001: Monday 
010: Tuesday 
011: Wednesday 
100: Thursday 
101: Friday 
110: Saturday 
111: Reserved (setting prohibited)