Renesas R5S72621 User Manual

Page of 2152
 
Section 14   Realtime Clock 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 681 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
14.3.4
 
Hour Counter (RHRCNT) 
RHRCNT is used for setting/counting in the BCD-coded hour section. The count operation is 
performed by a carry for each 1 hour of the minute counter. 
The assignable range is from 00 through 23 (practically in BCD), otherwise operation errors 
occur. Carry out write processing after stopping the count operation through the setting of the 
START bit in RCR2. 
Undefined Undefined Undefined Undefined Undefined Undefined
0
1
2
3
4
5
6
7
0
R/W
R/W
R/W
R/W
R/W
R/W
R
0
R
BIt:
Initial value:
R/W:
-
-
10 hours
1 hour
 
 
Bit Bit 
Name 
Initial 
Value R/W 
Description 
7, 6 
 All 
Reserved 
These bits are always read as 0. The write value should 
always be 0. 
5, 4 
10 hours 
Undefined  R/W 
Counting Ten's Position of Hours 
Counts on 0 to 2 for ten's position of hours. 
3 to 0 
1 hour 
Undefined  R/W 
Counting One's Position of Hours 
Counts on 0 to 9 once per hour.  When a carry is 
generated, 1 is added to the ten's position.