Renesas R5S72621 User Manual

Page of 2152
 
Section 14   Realtime Clock 
 
 
Page 680 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
14.3.3
 
Minute Counter (RMINCNT) 
RMINCNT is used for setting/counting in the BCD-coded minute section. The count operation is 
performed by a carry for each minute of the second counter. 
The assignable range is from 00 through 59 (practically in BCD), otherwise operation errors 
occur. Carry out write processing after stopping the count operation through the setting of the 
START bit in RCR2. 
Undefined Undefined Undefined Undefined Undefined Undefined Undefined
0
1
2
3
4
5
6
7
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
BIt:
Initial value:
R/W:
-
10 minutes
1 minute
 
 
Bit Bit 
Name 
Initial 
Value R/W 
Description 
 0 R 
Reserved 
This bit is always read as 0.The write value should 
always be 0. 
6 to 4 
10 minutes 
Undefined  R/W 
Counting Ten's Position of Minutes 
Counts on 0 to 5 for 60-minutes counting.  
3 to 0 
1 minute 
Undefined  R/W 
Counting One's Position of Minutes 
Counts on 0 to 9 once per second.  When a carry is 
generated, 1 is added to the ten's position.