Paradyne CSU User Manual

Page of 470
7. Operation and Maintenance
9128-A2-GB20-80
September 2002
7-9
ALM 
(cont'd)
Operational 
Alarm ( Fail)
Red
ON – FrameSaver unit has just been reset, or an 
error or fault has been detected. 
Alarms appear on the System and Test Status 
screen. See 
, for additional information.
OFF – No failures have been detected.
TST  
Test Mode   
Yellow
ON – Loopback or test pattern is in progress, 
initiated locally, remotely, or from the network.
OFF – No tests are active.
BKP  
Backup
Yellow
ON – FrameSaver unit is in Backup mode; that 
is, the backup link has been established, and 
backup is in progress through the specified 
Alternate Destination Link.
OFF – FrameSaver unit is not in Backup mode.
Blinking ON and OFF – Alternate Destination 
Link is being established, but no data has been 
passed.
FR 
Mode
2
(Model 
9128-II 
only)
Frame Relay 
Mode
Multi- 
colored
Yellow – LMI is down on the FrameSaver 
SLV 9128-II.
Green – LMI is up on the FrameSaver 
SLV 9128-II.
Table 7-1.
General Status LEDs (2 of 2) 
Label
Indiction
Color
What It Means
1
When an ISDN BRI DBM is installed, if the OK LED comes on then goes off during 
power recycling, the ISDN BRI DBM may have failed.
2
On the Display LEDs & Control Leads screen for the Model 9128-II only, FR Mode 
is On or Off. When On (highlighted), the FrameSaver unit is in Frame Relay mode.