Paradyne CSU User Manual

Page of 470
7. Operation and Maintenance
7-10
  
September 
2002
9128-A2-GB20-80
Table 7-2.
Network, DSX, or PRI Interface LEDs 
Label
Indication
Color
What It Means
SIG Signal
Green
ON 
– A recoverable signal is present on the 
Network/DSX/PRI interface.
OFF – The signal cannot be recovered from the 
Network/DSX/PRI interface. An LOS condition 
exists.
OOF
Out of Frame
Yellow
ON – At least one OOF was detected during the 
sampling period.
OFF – No OOFs were detected during the 
sampling period.
ALM  
Alarm
Yellow
ON – An alarm condition is present on the 
network/DSX/PRI interface.
Current alarm conditions: 
„
Loss of Signal ( LOS)
„
Loss of Frame (LOF)
„
Out of Frame (OOF)
„
Excessive Error Rate (EER)
„
Yellow Alarm Signal
„
Alarm Indication Signal (AIS)
OFF – No alarm condition is present on the 
Network/DSX/PRI interface.
Table 7-3.
User Data Port LED (CSU/DSUs Only)
Label
Indication
Color
What It Means
OK 
1
Operational 
Status
Green
ON – The interchange circuits for the port are in 
the correct state to transmit and receive data.
OFF – The port is idle. Occurs if the port is 
disabled, or if the port is configured to monitor 
DTR and/or RTS and the lead(s) is not asserted.
1
The FrameSaver SLV 9128-II only has one OK LED even though it has two user 
data ports. If either port is enabled and active, the LED is on. If both ports are 
enabled and one of the ports is inactive, the LED is off.
Table 7-4.
Ethernet Port LED (Routers Only)
Label
Indication
Color
What It Means
OK Operational 
Status
Green
ON – The Ethernet port is transmitting and 
receiving.
OFF – The port is idle.