Set-Up mode
Special mode
4-6
Options with Pre-determined Values
For some options, you can choose among a limited set of pre-determined values. To se-
lect such a value:
1
Repeatedly press the PARK/PRINT/
T
 key or the TEAR/
S
 key to position the 
value you require.
2
Press the FF/LOAD/Micro Feed Up/
X
 key to select the function. The printer 
prints the first parameter.
3
Press the SEL/MENU key to select the desired value and to activate the 
SAVE&EXIT position.
4
Press the SEL/MENU key again to save the new value and exit the Set-Up mode.
`
The printer exits the Set-Up mode and returns to the ready mode. The selected values 
remain in effect until the next time they are changed.
Example: Changing the Vertical Pitch
To become familiar with the Set-Up mode, try the following example. This example shows 
how to change the vertical pitch in COMMON (PUSH TRAC) from 6 lines per inch to 8 
lines per inch.
1
Enter the Set-Up mode: Turn the printer off and back on while pressing the SEL/
MENU key.
2
Select the COMMON (PUSH TRAC) function: Wait for the printer to stop print-
ing and press the PARK/PRINT/
T
 key five times to print the COMMON (PUSH 
TRAC) function.
3
Press the FF/LOAD/Micro Feed Up/
X
 key to print the PAPER SET parameter.
4
Press the PARK/PRINT/
T
 key to print the LPI parameter.
5
Press the FF/LOAD/Micro Feed Up/
X
 key to print the current LPI value (default: 
6 LPI).
6
Change the vertical pitch from 6 to 8 lines per inch. Press the PARK/PRINT/
T
 
key once to position the 8 LPI. Press the SEL/MENU key to select 8 LPI.
7
Press the SEL/MENU key to select 8 LPI and to activate the SAVE&EXIT posi-
tion.
8
Press the SEL/MENU key again to save the new value and exit the Set-Up mode 
and return to the Ready state. This setting remain in effect until the next time they are 