Enterasys mrxi-22 User Guide
LOCAL MANAGEMENT
5-14
To disconnect from a UPS through the Local Management:
1. Use the arrow keys to highlight the Serial Port 2 Application: field.
2. Press the Return key so that “OFFLINE” appears. You are now
disconnected from the UPS.
3. Use the arrow keys to highlight Disconnect? and press the Return
key.
4. Enter Y if you want to disconnect the UPS; N if you do not want to
disconnect. If you pressed Y, you are disconnected from the UPS.
5.4.6
Using the Port LOCK Override Option
When the chassis has been locked for security measures, unauthorized
devices will not be allowed to communicate to the MRXI. The Port
LOCK Override function provides a fail-safe recovery in the event that
the chassis cannot be unlocked via remote in-band management.
devices will not be allowed to communicate to the MRXI. The Port
LOCK Override function provides a fail-safe recovery in the event that
the chassis cannot be unlocked via remote in-band management.
To set the Port LOCK Override:
1. Use the arrow keys to highlight the Port LOCK Override field.
2. Press the Return key. The adjacent field displays “UNLOCK PORTS
Y/N”.
3. Enter Y to continue unlocking all of the ports, or N to discontinue the
port lock override. If you answer Y, all ports are unlocked and the
message “LOCK OVERRIDE COMPLETED” appears.
message “LOCK OVERRIDE COMPLETED” appears.
5.4.7
Using the Port ENABLE Override
The Port ENABLE Override function provides a fail-safe recovery in the
event that the ports on the MRXI cannot be enabled via remote in-band
management.
event that the ports on the MRXI cannot be enabled via remote in-band
management.