Installing the Switch on a Flat Surface
SecureStack A2 Installation Guide 
3-5
Guidelines for Flat Surface Installation
Locate the switch within 152 cm (5 ft) of its power source and on a surface as shown in 
. If an optional redundant power system is going to be installed and connected 
to the 14‐pin Redundant Power Supply input connector on the rear of the switch,
 
refer to 
the installation guide shipped with the redundant power system.
If you are installing several switches in a stack, proceed to “
on page 3‐7. If the switch is being installed as a standalone switch, proceed to “
” on page 3‐12 for power connection instructions.
Figure 3-2
 Area Guidelines for Switch Installation on Flat Surface
Caution: To ensure proper ventilation and prevent overheating, leave a minimum 
clearance space of 5.1 cm (2.0 in.) at the left, right, and rear of the switch. 
Do not connect the switch to the AC power source until instructed to do so later in the 
installation process.
Precaución: Para asegurar una buena ventilación y evitar que el sistema se 
sobrecaliente, deje un espacio mínimo de 5.1 cm (2 pulgadas) con respecto a los lados y 
a la parte posterior del aparato.
No conecte el dipositivo a la fuente primaria hasta que no se le indique.
1
Approximately 152 cm (5 ft) from power source
3
44.5 cm (19.4 in.) for proper ventilation
2
4.45 cm (1.75 in.) per switch. (Vertical clearance 
depends on number of switches stacked.)
4
41.9 cm (16.5 in.) for proper ventilation