Enterasys a2h123-24 User Manual

Page of 64
Connecting Stacking Cables
SecureStack A2 Installation Guide 
3-7
Figure 3-3
 Attaching the Rackmount Brackets
2.
With the mounting brackets attached, position the switch between the vertical frame 
members of the 19‐inch rack as shown in 
. Then fasten the switch securely 
to the frame using four mounting screws (user supplied). Refer to 
page A‐4 for recommended torque values by screw size.
Figure 3-4
 Fastening the Switch to the Rack
3.
If you are installing this switch in a stacked configuration, repeat this procedure for 
each switch until all switches have been installed in the stack, then proceed to 
” on page 3‐7. Otherwise, proceed to 
Connecting Stacking Cables
The stack of switches can be connected in a closed loop or daisy chained. In a closed loop, 
all the switches are connected in sequence and the last switch in the stack is connected 
back to the first switch. In a daisy chain configuration, the cable that would return the 
connection back to the first switch in a closed loop is not installed. The advantage of the 
closed loop is redundancy—this configuration eliminates any single point of failure. Up to 
eight switches can be stacked together and connected by standard UTP Category 5 or 
better cables. The stacking cables allow the entire stack to operate with a single IP address.
1
Rackmount brackets
2
M3x6 mm flathead screws
1
Rails of 19-inch rack
2
Mounting screws (supplied by user)