Inspecting Hoist Motion 
1.  Before closing the circuit breaker and testing 
the hoist, check that wiring has been complete. 
If the hoist cannot be observed when the 
circuit breaker is closed, station an observer 
within sight of the hoist to report any 
movement when power is applied to the hoist. 
Be prepared to disconnect power if hoist motor 
starts when the power is applied. The hoist 
must remain motionless when power is 
applied. Find and correct any problems before 
continuing. 
2.  With no load on the load hook, press the UP 
button very briefly and observe hoist action. 
The hook should move upward.  
3.  If no motion occurs when the UP button is 
pressed and the hoist is connected to a three 
phase power supply, the power supply wires 
are incorrectly positioned. Switch any two of 
the three supply wires at the power source. Do 
not attempt to rewire the hoist circuit or 
pendant controls for this problem.
 Use the 
same safety precautions when reversing two 
of the supply wires as was used when the 
wires were originally connected. 
4.  Re-connect power and test hoist movement 
again without load. Run hoist to the complete 
lifting height to ensure limit switches are 
operating properly. 
Extension Cords 
If an extension cord is necessary, make sure the 
cord rating is suitable for the amperage listed on 
the hoist's motor plate. An undersized cord will 
cause a drop in line voltage resulting in loss of 
power and overheating. 
The chart in Figure 6 shows the correct size cord to 
use based on cord length and motor plate amp 
rating. If in doubt, use the next heavier gauge. The 
smaller the gauge number, the heavier the cord. 
Reco m mended  Gauges (A W G) of Extension Cords  
Amps 
Extension Cord Length *  
25 
feet 
50 
feet 
75 
feet 
100 
feet 
150 
feet 
200 
feet 
16 16 16 14 12 12 
to 
8  16 16 14 12 10 NR 
to 
12  14 14 12 10 NR NR 
12 
to 
15 12 12 10 10 NR NR 
15 
to 
20 10 10 10 NR NR NR 
21 
to 
30  10  NR NR NR NR NR 
 
*based on limiting the line voltage drop to 5V at 150% of the 
rated amperes. 
NR: Not Recommended.
 
Figure 6 
Installing Chain Container 
Your hoist is supplied with a canvas chain 
container (Figure 7) designed to fit the particular 
length of chain. If a different length chain is ever 
installed on this hoist, the chain container must be 
replaced by one of proper size. See chart on page 
19. 
 Do not overfill chain container. 
If chain should overfill and begin to fall, the 
entire chain container may empty without 
warning, resulting in serious personal injury or 
property damage.
 
To assemble the chain container to the hoist: 
1.  Hang hoist in position on the I-Beam or trolley. 
Do not install chain container yet. Allow slack 
side and load side of chain to hang freely from 
hoist. 
2.  Apply power to the hoist and press the DOWN 
button until the lower limit switch is tripped. 
3.  Check the chain container to ensure that the 
seam is inside the bag. The bag must not be 
inside out.  
4.  Insert bracket prongs into interior bag slots 
(Figure 7) as far as they will go. 
 
Figure 7 
5.  Push the bracket down into the bag, making 
sure the flaps are raised (Figure 8). 
6.  Push the flaps over and down until they are 
secure (Figure 9).