2.  Open the connector caps on the two female 
connectors (Figure 2) and two male plugs 
(Figure 3). 
3.  Check orientation of notches on the female 
connectors and male plugs, and correctly 
insert the 4p plug into the 4p female connector 
on the left, insert the 7p plug into the 7p 
female connector on the right with sufficient 
force (see Figure 3). 
4.  Tighten the two cover nuts with fingers (see 
Figure 4). 
 
Figure 4 
Electrical Instructions 
 Electrical connections must be 
made by a qualified electrician in compliance 
with all relevant codes. This machine must be 
properly grounded to help prevent electrical 
shock and possible fatal injury.
 
Grounding 
In the event of a malfunction or breakdown, 
grounding provides a path of least resistance for 
electric current to reduce the risk of electric shock.  
This machine’s power cord must be fitted with an 
appropriate UL/CSA listed plug, or it can be “hard-
wired” directly to a control panel. If hard-wired, 
make sure a disconnect is available for the 
operator. 
If a plug is installed, it must have an equipment-
grounding conductor and a grounding prong. The 
plug must be plugged into a matching outlet that is 
properly installed and grounded in accordance with 
all local codes and ordinances.  
Do not modify the plug – if it will not fit the outlet, 
have the proper outlet installed by a qualified 
electrician. 
Improper connection of the equipment-grounding 
conductor can result in a risk of electric shock. The 
conductor with insulation having an outer surface 
that is green with or without yellow stripes is the 
equipment-grounding connector. 
If repair or replacement of the electric cord or plug 
is necessary, do not connect the equipment-
grounding conductor to a live terminal. 
Check with a qualified electrician or service 
personnel if the grounding instructions are not 
completely understood, or if in doubt as to whether 
the tool is properly grounded. 
Repair or replace damaged or worn cord 
immediately. 
Voltage Conversion 
The single phase model SS-1C is designed for 
115 volt or 230 volt operation. It is pre-wired for 
230 volt. To switch voltage: 
1.  Disconnect hoist from power supply, and 
unplug the power cord and pendant cord from 
the hoist. 
2.  Remove the motor cover and move the plug 
from the 230Vsocket to the 115V socket. 
3.  Re-install the motor cover. 
The  three phase model SS-3C is designed for 
230 volt or 460 volt operation. It is pre-wired for 
460V. To change to 230V proceed as follows.  
1.  Disconnect hoist from power supply, and 
unplug the power cord and pendant cord from 
the hoist. 
2.  Remove the motor cover and make the 
following exchanges on the SS-3C: 
Move the plug XP1 from socket XS2 to XS1. 
Move the plug XP2 from socket XS6 to XS5. 
3.  On the phase protector, slide the switch S1 
from the 460 volt position to the 230 volt 
position. 
4.  Re-install motor cover. 
Refer to the diagrams at the back of this manual for 
any clarification of these procedures. 
NOTE: When connecting plug to socket, check that 
the connector notch is fully engaged. To remove a 
plug, press on the notch tail to disengage notch. 
 
Figure 5 
(single speed model shown) 
Cover Nut