Maintenance
Note: During a One Night Process (ONP), a no restart switch activity
(SWACT) to the other central processing unit (CPU) drops active calls
on the ICB card. A warm SWACT of the front end during maintenance
activities does not affect active calls on the ICB card.
TCP/IP connectivity test
Maintenance technicians can use "ping" to test if the LAN connection is
installed and configured properly. Perform a ping test in one of the following
ways (they are equivalent so there is no need to try both):
from a computer on the local LAN to the ICB card’s IP address
from the CLI (under the SMaint/ directory) to the IP address of a
computer on the local LAN
CLI command summary
Using CLI commands
The CLI contains menus and submenus. To select a menu option, enter the
appropriate short command or full command at the prompt. When a menu
is selected, use the commands in
to navigate to other menus or to display help.
Table 43
Navigating the menus and displaying help
Command
Result
*
Returns to the previous menu.
/
Returns to the top menu level.
?
Displays help for the commands in the current menu.
When entering a menu option that has parameters defined, the "Modify,
Save, or Cancel:" command line displays so that the parameters can be
modified, if required.
To modify system parameters and objects, use one or more of the
commands in
and
Table 44
Modifying parameters
Command
Result
M
Modifies one or more parameters.
Nortel Communication Server 1000/Communication Server 2100 Solution/Meridian SL-100
Nortel Integrated Conference Bridge: Service Implementation Fundamentals
NN43001-558/555-4001-135
01.02
Standard
ICB Release 4
20 June 2007