Nortel 1000 User Guide

Page of 256
36
Engineering guidelines
Meridian 1 and CS 1000 software packages
In addition to standard basic software, the following software packages
are required:
ACD basic package (45)
ACD advanced features (41)
Digital set (88)
End-to-end signaling (10) - required if chairperson calls locally within
the same switch
Phantom TN (254), optional, but required if Phantom TN is used
Network ACD Enhanced Overflow (178), optional, but required for the
dual-card configuration
The following packages are optional, but are required for billing:
— Call Detail Recording (CDR) package 4
— CDR with Charge Account (CHG) package 23
— Charge Account/Authorization Code Base (CAB) package 24
Meridian SL-100 software packages
In addition to the standard Meridian SL-100 software, the following software
packages are required:
ACD Basic, ACD Routing Enhancement
MSL Digital Phones M2000-Display
MSL Flex LEN on IPE
MSL Enhanced Peripheral Equipment (IPE)
Hardware
describes the ICB hardware
specifications.
Table 2
Hardware specifications
Item
Descriptions
Port capacity
12-32 ports on a single card.
Up to 62 ports in a dual-card configuration, unless chairperson control is
required on the second card, in which case the capacity is 60 ports.
Capacity upgrades
Upgradeable from 12 to 62 ports.
Maximum number
of conferences
Up to 10 simultaneous conferences with a total of 32 conferee ports per
card.
Nortel Communication Server 1000/Communication Server 2100 Solution/Meridian SL-100
Nortel Integrated Conference Bridge: Service Implementation Fundamentals
NN43001-558/555-4001-135
01.02
Standard
ICB Release 4
20 June 2007
Copyright © 2007, Nortel Networks
.