Extreme x250e-24t Installation Instruction
Summit Family Switches Hardware Installation Guide
143
Installing an EPS-600LS Power Supply
To install an EPS-600LS unit into an EPS-C:
1
If necessary, remove a cover plate from a slot in the EPS-C.
2
Slide the EPS-600LS into an empty slot in the EPS-C (see
CAUTION
Be sure that empty slots in the EPS-C chassis are always covered by a cover plate when not in use. The EPS-C is
shipped with slots 2 and 3 covered and slot 1 open. Extreme Networks recommends that you populate slot 1
with an EPS-600LS unit first, but this is not required. You can install EPS-600LS units into any of the slots in
the EPS-C. The installation sequence does not affect the performance of the power supply units, but empty slots
must be covered at all times.
shipped with slots 2 and 3 covered and slot 1 open. Extreme Networks recommends that you populate slot 1
with an EPS-600LS unit first, but this is not required. You can install EPS-600LS units into any of the slots in
the EPS-C. The installation sequence does not affect the performance of the power supply units, but empty slots
must be covered at all times.
Figure 112: Installing the EPS-600LS Unit in the EPS-C Chassis
3
Slide the unit completely into the chassis until the front of the EPS-600LS is flush with the surface of
the EPS-C (see
the EPS-C (see
).
4
Tighten the two captive screws on the EPS-600LS unit into the EPS-C (see
). This secures
the unit in place.
EPS-C_04A